Also known as a fire trace tube system or thermally activated automatic fire suppression device. It uses a pressurized detection tube connected to an agent storage cylinder to detect heat and then discharges the extinguishing agent (CO₂, FM-200, or Novec 1230) either directly through the tube itself (direct type) or through a nozzle (indirect type). This system addresses the limitations of conventional fixed gas fire suppression systems in special applications where tight spaces or environmental constraints prevent the installation of piping, nozzles, or fire alarm systems. In such areas, traditional automatic systems cannot function, and portable extinguishers fail to suppress incipient fires, leading to significant economic losses.

Certifications

GAS-TRACE-TUB

Detailed information on product parameters
Model Application type Agent type Agent fill weight (kg) Cylinder volume (L) Storage pressure at 20°C (MPa) Safety relief pressure (MPa) Tube burst temp. (°C)
YF3/2.5N Direct Novec 1230 3 4 2.5 5.6±0.28 170±10
YF6/2.5N Direct Novec 1230 6 8 2.5 5.6±0.28 170±10
YF10/2.5N Indirect Novec 1230 10 10 2.5 5.6±0.28 170±10
TH-Z-Q-3/2.5/170 Direct FM-200 3 4 2.5 5.6±0.28 170±10
TH-Z-Q-6/2.5/170 Direct FM-200 6 10 2.5 5.6±0.28 170±10
TH-Z-Q-12/2.5/170 Indirect FM-200 12 20 2.5 5.6±0.28 170±10
TH-Z-E-6/170 Direct CO₂ 6 10 5.7 19±0.95 170±10
TH-Z-E-9/170 Direct CO₂ 9 20 5.7 19±0.95 170±10
TH-Z-E-42/170 Indirect CO₂ 42 70 5.7 19±0.95 170±10

 

Specifications

Fire detection tube type automatic fire extinguishing device

Detailed Table of System Devices

Model Application method Type of fire extinguishing agent fire extinguishing agentfilling quantity((Kg) Cylinder volume ( L ) storage pressure

(20C℃)

/MPa

Safe Release
Release pressure(MPa)
Fire detector tube
Blasting temperature
Degree( ℃ )
YF3/2.5Ne Direct type Perfluorohexane 3 4 2.5 5.6±0.28 170±10
YF6/2.5Ne 6 8
YF10/2.5Ne indirect 10 10
TH-Z-Q-3/2.5/170 Direct type heptafluoropropane 3 4
TH-Z-Q-6/2.5/170 6 10
TH-Z-Q-12/2.5/170 indirect 12 20
TH-Z-E-6/170 Direct type carbon dioxide 6 10 5.7 19±0.95
TH-Z-E-9/170 9 20
TH-Z-E-42/170 indirect 42 70

Certifications

Quality Assurance

Our systems are manufactured under strict quality control and certified by international bodies.

UL Listed

FM Approved

CE Certified

ISO 9001

ISO 14001

NFPA Compliant

Ready to Specify for Your Project?

Download the full technical datasheet or contact our engineering team for a customized proposal.