FM-200 Piped Fire Extinguishing System (GAS-FM200-PIP)
This piped FM-200 system delivers agent through a fixed pipe network to protected areas, features automatic alarm/interlock and manual override, and is ideal for large computer rooms and control centers.
Description
GAS-FM200-PIP
Product Description
This system is available in two pressure ratings: 4.2 MPa and 5.6 MPa. It consists of an automatic fire alarm and extinguishing control panel, agent storage containers, actuation containers, actuation valves, selector valves, check valves, signal feedback devices, safety valves, mounting brackets, nozzles, and piping networks. It provides automatic fire detection, alarm, equipment interlock control, and agent discharge. In emergency situations, it can be activated via electric manual or mechanical manual override.
Primarily used for fire protection in computer rooms, data processing centers, telecommunications facilities, control centers, high-value medical facilities, valuable industrial equipment, museums and art galleries, libraries, archives, valuables storage rooms, emergency power facilities, and cleanrooms.
Certifications
GAS-FM200-PIP
Detailed information on product parameters
| Model | Volume (L) | Discharge time (s) | Operating temp. (°C) | Storage pressure at 20°C (MPa) | Max. pressure (MPa) | Max. filling ratio (kg/m³) |
| QMQ70/4.2N | 70 | ≤10 | 0~50 | 4.2 | 5.3 | ≤950 |
| QMQ90/4.2N | 90 | ≤10 | 0~50 | 4.2 | 5.3 | ≤950 |
| QMQ100/4.2N | 100 | ≤10 | 0~50 | 4.2 | 5.3 | ≤950 |
| QMQ120/4.2N | 120 | ≤10 | 0~50 | 4.2 | 5.3 | ≤950 |
| QMQ150/4.2N | 150 | ≤10 | 0~50 | 4.2 | 5.3 | ≤950 |
| QMQ180/4.2N | 180 | ≤10 | 0~50 | 4.2 | 5.3 | ≤950 |
| QMQ70/5.6N | 70 | ≤10 | 0~50 | 5.6 | 8.0 | ≤1080 |
| QMQ90/5.6N | 90 | ≤10 | 0~50 | 5.6 | 8.0 | ≤1080 |
| QMQ120/5.6N | 120 | ≤10 | 0~50 | 5.6 | 8.0 | ≤1080 |
Specifications
Pipeline type heptafluoropropane automatic fire extinguishing system
Detailed Table of System Devices
| model | volume(L) | Spray time(S) | Operating temperature (℃) | 20℃Storage pressure(Mpa) | maximum pressure(Mpa) | Maximum filling rate(kg/m³) |
| QMQ70/4.2N | 70 | ≤10 | 0~50 | 4.2 | 5.3 | ≤950 |
| QMQ90/4.2Ne | 90 | ≤10 | 0~50 | 4.2 | 5.3 | ≤950 |
| QMQ100/4.2N | 100 | ≤10 | 0~50 | 4.2 | 5.3 | ≤950 |
| QMQ120/4.2N | 120 | ≤10 | 0~50 | 4.2 | 5.3 | ≤950 |
| QMQ150/4.2N | 150 | ≤10 | 0~50 | 4.2 | 5.3 | ≤950 |
| QMQ180/4.2N | 180 | ≤10 | 0~50 | 4.2 | 5.3 | ≤950 |
| QMQ70/5.6N | 70 | ≤10 | 0~50 | 5.6 | 8.0 | ≤1080 |
| QMQ90/5.6N | 90 | ≤10 | 0~50 | 5.6 | 8.0 | ≤1080 |
| QMQ120/5.6N | 120 | ≤10 | 0~50 | 5.6 | 8.0 | ≤1080 |
Certifications
Quality Assurance
Our systems are manufactured under strict quality control and certified by international bodies.
UL Listed
FM Approved
CE Certified
ISO 9001
ISO 14001
NFPA Compliant
Ready to Specify for Your Project?