China Unicom Equipment Room Piped FM-200 System

The equipment room is a core node of the local communication network with high electrical fire risk; a clean gas fire suppression system is mandatory.

Description

China Unicom Equipment Room Piped FM-200 System

Product Description

The computer room carries the core communication exchange, data transmission, broadband access, and government enterprise customer services in the area, and is the core node of the local communication network. Once a fire occurs, it will directly affect public communication, government affairs, and livelihood services, with significant social impact and high economic losses. Servers and switches in the computer room UPS、 Long term live operation of battery cabinets and dense cables can easily lead to electrical fires due to aging, poor contact, overload, and poor heat dissipation, making them high-risk locations. According to the communication industry’s fire safety standards and network security level protection requirements, the core computer room must be equipped with a clean gas automatic fire extinguishing system.

Project Objective

China Unicom Equipment Room Piped FM-200 System

Introduction to project objectives

3.1 Safety objective: In the event of an electrical fire in the computer room, the system can quickly detect, automatically link, and reliably extinguish the fire within 8 seconds, preventing the spread of the fire, ensuring personnel safety, and avoiding major fire accidents.
3.2 Protection Objective: After extinguishing the fire, there should be no residue, corrosion, or water stains, and no damage to servers, switches, storage devices, and cables. Hardware equipment and business data should be maximally protected to reduce post disaster recovery costs.
3.3 Business Continuity Objective: To achieve uninterrupted fire extinguishing, rapid equipment restart, shorten business interruption time, and ensure the continuous and stable operation of communication networks and government enterprise customer businesses.
3.4 Compliance Objective: The system design, construction, and acceptance fully comply with national and communication industry standards, and eliminate compliance risks through fire safety acceptance and security evaluation.
3.5 Operation and Maintenance Management Objectives: The system is stable and reliable, easy to maintain, and has remote monitoring and linkage capabilities. It seamlessly integrates with existing fire alarm, security, and UPS systems to enhance the overall intelligent security level of the computer room.

Project achievements

China Unicom Equipment Room Piped FM-200 System

Introduction to project achievements

Install a complete pipe network heptafluoropropane fire extinguishing system: divide according to the protection zone, complete the installation and commissioning of equipment such as steel cylinder group, pipe network, nozzle, starting bottle, control panel, smoke and temperature detection, sound and light alarm, gas release indicator light, emergency start stop button, pressure relief port, etc. The system linkage is reliable and the response is fast.